Note that the full install is about 90MB.
SP3 - Available June 19, 2003 - Build 2003.03.13--- Changes
- Fixed: The optimizer was not always converging as quickly as it should,
it was following a suboptimal path.
- Fixed: The optimizer was redrawing the schematic too often, slowing
it substantially.
- Fixed: Harbec HB analysis had frequency interpolation issues.
- Fixed: GDS export had issues with units of measure and vias.
- Fixed: the DEFAULT.EG$ file was incorrect for TLine and PLL (not
available
in the patch, but see the forum for info on how to manually
fix this).
- Fixed: Non-reciprocal noise handling in Spectrasys is now correct.
- Fixed: Schematic units of measure can now be changed.
- Fixed: The GENESYS License Server now works in Windows 98.
- Improved: Advanced TLine conversion is more accurate for coupled
lines.
- Improved: GENESYS now loads the LDMOS libraries more quickly.
- Improved: Authorization for network licenses has better error checking
when
filling the network list.
- Improved: Authorization prompts are more accurate for GENESYS Personal.
- Improved: When adding high-accuracy models, the auto designators
are now R,L, and C.
- Added: Two new measurements for Spectrasys, PRNF (percent Noise
Figure)
and PRIM3 (percent Intermod)
- Added: A new VBIC transistor model
SP2 is the second service pack for GENESYS 2003.03. This is build #12.
Changes for 2003.03 SP2
- Some files with HARBEC analyses would not load correctly.
SP1 is the first service pack for GENESYS 2003.03. This is build #11.
Changes for 2003.03 SP1
- Link to S-Parameter data files now correctly parses frequencies
in scientific notation
- SFilter is now reliable with no default file.
- Fixed linkage to user defined symbols in loaded workspaces
- Gain compression was added to the Attenuator, Variable Attenuator,
and Switch models
- Updated the channel frequency measurements of Offset Channel Frequency,
Tone Channel Frequency, and Adjacent Channel Frequency to account
for sideband inversions when using LO high side injection mixers
- Improved default values for the modulated source in Spectrasys
- Default order has been set to 3 for Microwave Filter Synthesis
- Empower now responds to the Esc key more than once
- Changing frequency ranges now correctly updates data
- Layout grids now correctly line up with empower grids
- Pours over polygons now work correctly.
- EMPOWER failure error messages are now visible.
- Certain complex workspaces that would hang on load now load correctly.
- Tuned equation lines can now have trailing comments.
- Authorize now correctly works with GENESYS Personal.
- Windows NT now correctly brings up the right mouse menus in the
workspace tree.
- Windows NT now loads the LDMOS libraries.
- The Japanese language version now correctly edits substrates.
- HARBEC will now correctly analyze non-linear circuits that used
to have oscillator ports.
Mark Zachmann
|
 |

|